- Servomechanism Definition: A servomechanism is an automated control system designed to maintain system output at a desired level using feedback loops.
- Components: The system includes a controlled device, an output sensor, and a feedback system to monitor and adjust the device’s performance.
- Servo Motor Basics: A servo motor consists of a small DC motor equipped with a gear system and a potentiometer for precise control.
- Working Principle of Servo Motor: The servo motor adjusts its position by comparing the feedback from the potentiometer with an external command, stopping when both match.
- Application: This precise control makes servo motors ideal for applications where accurate positioning is crucial.
Servo Motor Working Principle
Before we explore the working principle of servo motor, let’s first grasp the basics of a servomechanism.
What is Servomechanism?
A servo system primarily consists of three basic components – a controlled device, a output sensor, a feedback system.
A servomechanism is an automatic closed loop control system that regulates a device using a feedback signal. This signal is generated from the differences between the output and a reference input.
When reference input signal or command signal is applied to the system, it is compared with output reference signal of the system produced by output sensor, and a third signal produced by a feedback system. This third signal acts as an input signal of controlled device.
The input signal continues to adjust the device as long as there is a discrepancy between the reference input and the system’s output signal.
After the device achieves its desired output, there will be no longer the logical difference between reference input signal and reference output signal of the system. Then, the third signal produced by comparing theses above said signals will not remain enough to operate the device further and to produce a further output of the system until the next reference input signal or command signal is applied to the system.
Hence, the primary task of a servomechanism is to maintain the output of a system at the desired value in the presence of disturbances.
Working Principle of Servo Motor
A servo motor is basically a DC motor (in some special cases it is AC motor) along with some other special purpose components that make a DC motor a servo. In a servo unit, you will find a small DC motor, a potentiometer, gear arrangement and an intelligent circuitry. The intelligent circuitry along with the potentiometer makes the servo to rotate according to our wishes. As we know, a small DC motor will rotate with high speed but the torque generated by its rotation will not be enough to move even a light load.
This is where the gear system inside a servomechanism comes into the picture. The gear mechanism will take high input speed of the motor (fast) and at the output, we will get an output speed which is slower than original input speed but more practical and widely applicable.
Initially, the servo motor shaft is positioned so that the potentiometer knob generates no signal. This output from the potentiometer and an external signal are fed into an error detector amplifier. The amplifier then boosts the difference between these signals to control the motor.
This amplified error signal acts as the input power of the DC motor and the motor starts rotating in desired direction. As the motor shaft progresses the potentiometer knob also rotates as it is coupled with motor shaft with help of gear arrangement.
As the potentiometer knob turns, it generates a signal that increases with its rotation. Once it reaches the desired position, this signal matches the external signal provided to the amplifier, causing the motor to stop.
At this condition, there will be no output signal from the amplifier to the motor input as there is no difference between external applied signal and the signal generated at potentiometer. As the input signal to the motor is nil at that position, the motor stops rotating. This is how a simple conceptual servo motor works.